Strona 1 - Oracle Acme Packet 6100

Oracle Acme Packet 6100Hardware Installation and Maintenance GuideApril 2015

Strona 2

2 Acme Packet 6100 Hardware Installation and Maintenance GuideElectrical Safety PrecautionsTo protect yourself from harm and the Acme Packet 6100 fro

Strona 3 - Contents

92 Acme Packet 6100 Hardware Installation and Maintenance GuideInstalling the Chassis in the RackPerform the reverse of the operations in the Physica

Strona 4

Acme Packet 6100 Hardware Installation and Maintenance Guide 93Optical Transceiver Removal and ReplacementYour troubleshooting and diagnostics might

Strona 5

94 Acme Packet 6100 Hardware Installation and Maintenance GuideThe single mode SFP+ transceiver for the Acme Packet 6100 features a blue clasp latch.

Strona 6

Acme Packet 6100 Hardware Installation and Maintenance Guide 95Caution To prevent damage to the optical lens, Acme Packet recommends that the protect

Strona 7 - About This Guide

96 Acme Packet 6100 Hardware Installation and Maintenance Guide3. Holding the extended bale clasp latch with one hand, use your other hand to pull th

Strona 8 - Revision History

Acme Packet 6100 Hardware Installation and Maintenance Guide 973. Flip the bale clasp latch back into the rest position. Figure 6 - 132. Closing the

Strona 9 - 1 Safety

98 Acme Packet 6100 Hardware Installation and Maintenance GuideFan and Filter MaintenanceThis section explains how to remove a fan and replace the fi

Strona 10 - Battery Warning

Acme Packet 6100 Hardware Installation and Maintenance Guide 992. Using a small bladed screwdriver, unscrew the two captive screws at each corner of

Strona 11 - ESD Safety

100 Acme Packet 6100 Hardware Installation and Maintenance GuideFigure 6 - 138. Inserting the Fan into the Chassis Slot 2. Using a small bladed screw

Strona 12

Acme Packet 6100 Hardware Installation and Maintenance Guide 101requires that you remove the module itself. If you are not shutting down the Acme Pac

Strona 13 - 2 Component Overview

Acme Packet 6100 Hardware Installation and Maintenance Guide 3ESD Safety To protect the Acme Packet 6100 delicate electronic components from damage f

Strona 14

102 Acme Packet 6100 Hardware Installation and Maintenance GuideFigure 6 - 143. Removing the Air Filter from Behind the Front Bezel 5. Replace the ai

Strona 15 - System Control Panels

Acme Packet 6100 Hardware Installation and Maintenance Guide 1038. Place the air filter bracket behind the air filter, ensuring that the bracket lock

Strona 16

104 Acme Packet 6100 Hardware Installation and Maintenance Guide• Fan speed• Environmental sensor• Power supply• Voltage• Physical interface cardsEac

Strona 17 - LINK ACT LINK ACT

Acme Packet 6100 Hardware Installation and Maintenance Guide 105Fan Speed Alarms The following table lists the fan speed alarm. Table 6 - 10. Fan Spe

Strona 18 - Network Interface Unit

106 Acme Packet 6100 Hardware Installation and Maintenance GuideVoltage Alarms The following table lists the voltage alarms.Table 6 - 13. Voltage Ala

Strona 19 - Figure 2 - 19. USB Port

Table 6 - 15. Media Ethernet Link Alarm Information Alarm NameAlarm IDAlarm Severity Cause(s)Example Log MessageGraphic Display MessageLINK UP ALARM 1

Strona 20 - Figure 2 - 20. Console Port

108 Acme Packet 6100 Hardware Installation and Maintenance GuideWhen an SFP module is inserted or removed from an NIU, there is no impact on system h

Strona 21 - Table 2 - 2. Alarm Levels

Acme Packet 6100 Hardware Installation and Maintenance Guide 1097 SpecificationsIntroductionThis chapter provides information regarding the physical

Strona 22 - Management Ports

110 Acme Packet 6100 Hardware Installation and Maintenance GuideDC Power Supply Physical DimensionsThis table lists the physical dimensions and weigh

Strona 23 - Media Interfaces

Acme Packet 6100 Hardware Installation and Maintenance Guide 111Device Ratings This table lists the alarm device ratings of the Acme Packet 6100.Tab

Strona 24 - Power Components

4 Acme Packet 6100 Hardware Installation and Maintenance Guide

Strona 25 - Redundancy

112 Acme Packet 6100 Hardware Installation and Maintenance GuideOptical Transceiver Interface Module SpecificationRefer to the following table for in

Strona 26

Acme Packet 6100 Hardware Installation and Maintenance Guide 1138 GlossaryAcronyms, Definitions, and TermsACLI — Acme Command Line Interface is the

Strona 27

114 Acme Packet 6100 Hardware Installation and Maintenance GuideIEC — International Electrotechnical CommissionIETF — Internet Engineering Task Force

Strona 28 - Cooling Components

Acme Packet 6100 Hardware Installation and Maintenance Guide 115SDRAM — Synchronous Dynamic Random Access Memory is a type of DRAM that can run at mu

Strona 29

116 Acme Packet 6100 Hardware Installation and Maintenance Guide

Strona 30

Acme Packet 6100 Hardware Installation and Maintenance Guide 117Index AAC power supply, physical dimensions of 109ACLI authentication 58acronyms 113A

Strona 31 - 3 Graphic Display

118 Acme Packet 6100 Hardware Installation and Maintenance Guideconsole session 57control panelfront 9rear 9cooling components 20air inlets 20mainten

Strona 32 - Graphic Display Menus

Acme Packet 6100 Hardware Installation and Maintenance Guide 119link up/link down alarm information 106log in, initial 58logging in 58Mmanagement int

Strona 33

120 Acme Packet 6100 Hardware Installation and Maintenance Guidepower supply removal and replacement 68powering on the chassis 58pre-installation 32R

Strona 34 - BOOT PARAMS

Acme Packet 6100 Hardware Installation and Maintenance Guide 52 Component OverviewChassisThe Acme Packet 6100 is contained in a 1U rack-mounted chas

Strona 35

6 Acme Packet 6100 Hardware Installation and Maintenance Guideprevent the chassis from being overextended and requiring the user to unlock the clip t

Strona 36 - ENVIRONMENT

Acme Packet 6100 Hardware Installation and Maintenance Guide 7Figure 2 - 9. Locking Clip Fastens the Chassis and Rack Slide Rails Once the chassis h

Strona 37

8 Acme Packet 6100 Hardware Installation and Maintenance Guidereset button, alarm LED, alarm silence button, console port, and USB port. The followin

Strona 38

Acme Packet 6100 Hardware Installation and Maintenance Guide 9Alarm LED The alarm LED on the front control panel indicates if any alarms are active o

Strona 39 - 4 System Installation

10 Acme Packet 6100 Hardware Installation and Maintenance GuideNetwork Interface UnitThe single, hot-pluggable network interface unit (NIU) contains

Strona 40 - Pre-Installation Guidelines

Acme Packet 6100 Hardware Installation and Maintenance Guide 11other power switches. The System Power switch, located on the front panel of the NIU,

Strona 41 - Mounting Installation

Copyright © 2014, 2015 Oracle and/or its affiliates. All rights reserved.This software and related documentation are provided under a license agreemen

Strona 42

12 Acme Packet 6100 Hardware Installation and Maintenance GuideConsole Port The console port, located on the Acme Packet 6100 front panel, provides

Strona 43 - • Nut Bar (4)

Acme Packet 6100 Hardware Installation and Maintenance Guide 13Figure 2 - 21. Console Adapter Alarm Port The alarm port on the NIU is a flexible inte

Strona 44 - • Mounting Spacer (2)

14 Acme Packet 6100 Hardware Installation and Maintenance GuideNetwork Management PortsThe Acme Packet 6100 has three network management ports locate

Strona 45 - Slide Rails

Acme Packet 6100 Hardware Installation and Maintenance Guide 15Ethernet ports for use. Set up the management interfaces using the physical and networ

Strona 46

16 Acme Packet 6100 Hardware Installation and Maintenance GuidePWR LED The green PWR LED indicates the operational state of the NIU. Mgmt 2Mgmt 1Mgm

Strona 47

Mgmt 2Mgmt 1Mgmt 0USBAlarmConsoleSystemPower OnStbyStbyDisLINK ACT LINK ACTPWR H/SPower Supply BPower Supply AGrounding TerminalsAcme Packet 6100 H

Strona 48

18 Acme Packet 6100 Hardware Installation and Maintenance Guidegrey locking handle, when moved from right to left, unlocks the power supply from the

Strona 49 - Chassis Flanges

Handle to Remove/Insert Power SupplyLocking Tab to Lock/Unlock Power Supply to Acme Packet 6100Acme Packet 6100 Hardware Installation and Maintenance

Strona 50

20 Acme Packet 6100 Hardware Installation and Maintenance GuideCooling ComponentsThe Acme Packet 6100 must remain well ventilated for reliable and co

Strona 51 - Chassis in the

Acme Packet 6100 Hardware Installation and Maintenance Guide 21Acme Packet 6100 Series Hardware ArchitectureThe Acme Packet 6100 series hardware is p

Strona 52 - Hardware

Acme Packet 6100 Hardware Installation Guide iiiContentsAbout This Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 53

22 Acme Packet 6100 Hardware Installation and Maintenance Guide

Strona 54 - Fan Module Installation

Acme Packet 6100 Hardware Installation and Maintenance Guide 233 Graphic DisplayGraphic DisplayThe four-line graphic display located on the Acme Pac

Strona 55 - Installation

24 Acme Packet 6100 Hardware Installation and Maintenance GuideDisplay ModesThe Acme Packet 6100 graphic display defaults to one of two display modes

Strona 56 - AC Power Cord

Acme Packet 6100 Hardware Installation and Maintenance Guide 25The top menu displays only one category at a time. Press the Enter button to select a

Strona 57

26 Acme Packet 6100 Hardware Installation and Maintenance GuideINTERFACE Menu The INTERFACE menu allows you to scroll through a list of all configure

Strona 58 - DC Power Cord

Acme Packet 6100 Hardware Installation and Maintenance Guide 27SYSTEM Menu The SYSTEM menu allows you to view system software, current time, and sysl

Strona 59 - Cabling the Acme Packet 6100

28 Acme Packet 6100 Hardware Installation and Maintenance Guide• Screen 4 — SNMP information: number of SNMP packets received, number of SNMP traps s

Strona 60 - Figure 4 - 77. Console Port

Acme Packet 6100 Hardware Installation and Maintenance Guide 29Graphic Display Output for HA NodesThe information included in this section only appli

Strona 61 - Interfaces

30 Acme Packet 6100 Hardware Installation and Maintenance Guide

Strona 62

Acme Packet 6100 Hardware Installation and Maintenance Guide 314 System InstallationIntroductionThis chapter provides information about how to insta

Strona 63 - Cabling for HA Deployments

iv Acme Packet 6100 Hardware Installation Guide 4 System Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 64

32 Acme Packet 6100 Hardware Installation and Maintenance GuideRecommended Tools and PartsAcme Packet recommends that you have the following parts on

Strona 65 - 5 Startup

Acme Packet 6100 Hardware Installation and Maintenance Guide 33console connector, reset button, graphic display buttons, and physical interface card

Strona 66 - Password:

34 Acme Packet 6100 Hardware Installation and Maintenance GuideUnpacking the Acme Packet 6100To unpack the Acme Packet 6100:1. Inspect the external p

Strona 67 - Solid State Drive

Acme Packet 6100 Hardware Installation and Maintenance Guide 35• Equipment rack slide rail (part of the slide rail assembly) Figure 4 - 39. Equipmen

Strona 68

36 Acme Packet 6100 Hardware Installation and Maintenance Guide• Mounting Spacer (2) Figure 4 - 42. Mounting Spacer • Phillips screws and flat head s

Strona 69 - 6 Maintenance Introduction

Acme Packet 6100 Hardware Installation and Maintenance Guide 37Mounting System Acme Packet provides flexible mounting options for your Acme Packet 61

Strona 70

38 Acme Packet 6100 Hardware Installation and Maintenance Guide3. For both holes in the flange, place one #10-32 x 5/8” screw through the mounting sp

Strona 71 - Acme Packet

Acme Packet 6100 Hardware Installation and Maintenance Guide 396. For both holes in the slide rail flange, place one #10-32 x 5/8” screw through the

Strona 72

40 Acme Packet 6100 Hardware Installation and Maintenance Guide2. Line up the painted side of the stationary rail with an appropriate mount point on

Strona 73

Acme Packet 6100 Hardware Installation and Maintenance Guide 416. Expand and line up the unpainted side of the stationary rail flange on the outside

Strona 74 - Replacing an NIU

Acme Packet 6100 Hardware Installation Guide v7 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .

Strona 75 - Chassis Removal

42 Acme Packet 6100 Hardware Installation and Maintenance Guide2. Line up one chassis flange with the tapped holes. Position the chassis flange’s spr

Strona 76

Acme Packet 6100 Hardware Installation and Maintenance Guide 43Installing the Chassis in the RackThe Acme Packet 6100 is now ready to be installed in

Strona 77

44 Acme Packet 6100 Hardware Installation and Maintenance Guide4. Line up the chassis-mounted thumbscrews with the threads on the Acme Packet 6100 mo

Strona 78

Acme Packet 6100 Hardware Installation and Maintenance Guide 45To install your Acme Packet 6100 in a center-mount configuration: 1. Locate the follow

Strona 79 - NIU Removal and Replacement

46 Acme Packet 6100 Hardware Installation and Maintenance Guideshould hold the Acme Packet 6100 in the correct position while the other person screws

Strona 80

Acme Packet 6100 Hardware Installation and Maintenance Guide 47Caution The Acme Packet 6100 does not support mixing AC and DC power supplies in the s

Strona 81

48 Acme Packet 6100 Hardware Installation and Maintenance Guide2. Place the lug on the end of the grounding cable onto the grounding posts. Figure 4

Strona 82 - Replacing the SSM3 Module

Acme Packet 6100 Hardware Installation and Maintenance Guide 491. Set the System Power switch to the Stby position to cut off power to the Acme Packe

Strona 83 - Guidelines

50 Acme Packet 6100 Hardware Installation and Maintenance GuideDC Power Cord InstallationThis section shows you how to install a DC power cord.Cautio

Strona 84 - SSM3 Module

Acme Packet 6100 Hardware Installation and Maintenance Guide 514. Connect the plug from another 3-conductor power cord to the power connector located

Strona 85

vi Acme Packet 6100 Hardware Installation Guide

Strona 86 - Installing SODIMMs

52 Acme Packet 6100 Hardware Installation and Maintenance GuideNote: Intra-building ports include Media and Signaling Network Interfaces, Network Ma

Strona 87

Acme Packet 6100 Hardware Installation and Maintenance Guide 532. Insert the RJ45 connector on the end of the alarm port cable into the alarm port la

Strona 88 - SODIMM(s)

54 Acme Packet 6100 Hardware Installation and Maintenance Guide10GbE SFP Optical Cabling ProcedureThis section explains how to cable a Acme Packet 61

Strona 89

Acme Packet 6100 Hardware Installation and Maintenance Guide 554. Repeat Steps 1 through 2 for each additional fiber optic cable you connect to your

Strona 90

56 Acme Packet 6100 Hardware Installation and Maintenance Guide3. Refer to the configuration procedures located in the HA Nodes chapter of the Acme P

Strona 91 - Installation Tools

Acme Packet 6100 Hardware Installation and Maintenance Guide 575 StartupIntroductionThis chapter describes Acme Packet 6100 startup which involves t

Strona 92

58 Acme Packet 6100 Hardware Installation and Maintenance Guide4. If you have created the console connection before powering up the Acme Packet 6100,

Strona 93 - Figure 2 - 33 Left rack ear

Acme Packet 6100 Hardware Installation and Maintenance Guide 59System access in the following procedure uses the default User and Superuser passwords

Strona 94

60 Acme Packet 6100 Hardware Installation and Maintenance Guide

Strona 95 - Replacing the

Acme Packet 6100 Hardware Installation and Maintenance Guide 616 Maintenance IntroductionIntroductionThis chapter explains Acme Packet 6100 hardware

Strona 96

Acme Packet 6100 Hardware Installation and Maintenance Guide vii About This GuideOverviewThe Acme Packet 6100 is a session border controller (SBC)

Strona 97

62 Acme Packet 6100 Hardware Installation and Maintenance GuideRebooting, Resetting, and Power CyclingReboot Rebooting the Acme Packet 6100 shuts dow

Strona 98

Acme Packet 6100 Hardware Installation and Maintenance Guide 63During a system reset, certain files are not closed properly, and they may become corr

Strona 99

64 Acme Packet 6100 Hardware Installation and Maintenance GuideOnce you have determined that the Acme Packet 6100 due for maintenance is in standby m

Strona 100

NETNETSBC1# show health Media Synchronized true SIP Synchronized true MGCP Synchronized true

Strona 101

66 Acme Packet 6100 Hardware Installation and Maintenance Guide2. Confirm that current configurations of both the active and standby Acme Packet 6100

Strona 102 - Media Cables

Acme Packet 6100 Hardware Installation and Maintenance Guide 67When this Acme Packet 6100 returns online, it will synchronize its HA state with the a

Strona 103

68 Acme Packet 6100 Hardware Installation and Maintenance Guide6. When mounted in slide rails, the chassis will stop when the locking clip pin on the

Strona 104

Acme Packet 6100 Hardware Installation and Maintenance Guide 69power supply, remember to first ground yourself using appropriate ESD grounding equipm

Strona 105

70 Acme Packet 6100 Hardware Installation and Maintenance Guide4. Continue pulling the power supply towards you until it is completely out of the cha

Strona 106 - Fan and Filter Maintenance

Acme Packet 6100 Hardware Installation and Maintenance Guide 71NIU Removal and ReplacementPrior to removing an NIU, the platform in which it is insta

Strona 107 - Install Individual

viii Acme Packet 6100 Hardware Installation and Maintenance GuideRevision HistoryThis section contains a revision history for this document.Date Desc

Strona 108 - Components

72 Acme Packet 6100 Hardware Installation and Maintenance Guide6. Pull the loosened NIU out of the Acme Packet 6100 by holding each side of the NIU’s

Strona 109

Acme Packet 6100 Hardware Installation and Maintenance Guide 735. Slide the card into the Acme Packet 6100. The physical interface card circuit board

Strona 110

74 Acme Packet 6100 Hardware Installation and Maintenance Guide8. Screw the NIU into the chassis with a #2 Phillips screwdriver. This creates the fin

Strona 111

Acme Packet 6100 Hardware Installation and Maintenance Guide 75connector supports one side of the module while the other side of the SSM3 module rest

Strona 112 - Environmental

76 Acme Packet 6100 Hardware Installation and Maintenance GuideRequired Parts The following parts are required to replace the SSM3 module:• ESD wris

Strona 113 - Environmental Sensor

Acme Packet 6100 Hardware Installation and Maintenance Guide 77• Standoff screws (stored after removing the SSM3 module or available with the new SSM

Strona 114 - Link and SDP

StandoffsSSM3 Module78 Acme Packet 6100 Hardware Installation and Maintenance GuideFigure 6 - 109. Location of the SSM3 Module Standoff Posts Instal

Strona 115 - Link Alarms

Acme Packet 6100 Hardware Installation and Maintenance Guide 79Figure 6 - 111. Process for Installing the SODIMM (l-r) Pre-Installation Guidelines P

Strona 116

80 Acme Packet 6100 Hardware Installation and Maintenance Guide• ESD wrist strap• ESD safe location• SODIMM(s) • NIU Card Removing the SODIMM(s)The f

Strona 117 - 7 Specifications

Acme Packet 6100 Hardware Installation and Maintenance Guide 815. Grasping the SODIMM between your thumb and index finger, pull the component out of

Strona 118 - Electrical Specifications

Acme Packet 6100 Hardware Installation and Maintenance Guide 11 Safety IntroductionThis chapter provides an overview of the recommended safety preca

Strona 119 - Connector Specifications

82 Acme Packet 6100 Hardware Installation and Maintenance GuideFigure 6 - 116. Installing the SODIMM (l-r) 5. Using the index finger and thumb of yo

Strona 120 - Specifications

Acme Packet 6100 Hardware Installation and Maintenance Guide 83Upgrading or Replacing a Solid State Drive This section explains how to upgrade or rep

Strona 121 - 8 Glossary

84 Acme Packet 6100 Hardware Installation and Maintenance GuideThe following is an overview of the power and ground cabling removal process:1. Shut o

Strona 122

Acme Packet 6100 Hardware Installation and Maintenance Guide 85Removing Hardware in Center-Mount ConfigurationsThe rack ears must be removed before y

Strona 123

86 Acme Packet 6100 Hardware Installation and Maintenance GuideFigure 6 - 118: Figure 2 - 35: Left chassis slide.3. Remove the the two countersunk sc

Strona 124

Acme Packet 6100 Hardware Installation and Maintenance Guide 872. Set these screws aside.REARFRONT3. Unscrew the seven countersunk screws on the top

Strona 125

88 Acme Packet 6100 Hardware Installation and Maintenance Guide1. The SSD is located at the front of the motherboard, on the left side as you view it

Strona 126

Acme Packet 6100 Hardware Installation and Maintenance Guide 893. Identify the SATA connector attached to the SSD.REARFRONT Screws SATAConnection to

Strona 127

90 Acme Packet 6100 Hardware Installation and Maintenance Guide5. Hold the SSD in one hand, and the SATA connector in the other, and gently disconnec

Strona 128

Acme Packet 6100 Hardware Installation and Maintenance Guide 91Postinstallation After the Solid State Drive has been installed in the Acme Packet 610