Oracle Acme Packet 6100Hardware Installation and Maintenance GuideApril 2015
2 Acme Packet 6100 Hardware Installation and Maintenance GuideElectrical Safety PrecautionsTo protect yourself from harm and the Acme Packet 6100 fro
92 Acme Packet 6100 Hardware Installation and Maintenance GuideInstalling the Chassis in the RackPerform the reverse of the operations in the Physica
Acme Packet 6100 Hardware Installation and Maintenance Guide 93Optical Transceiver Removal and ReplacementYour troubleshooting and diagnostics might
94 Acme Packet 6100 Hardware Installation and Maintenance GuideThe single mode SFP+ transceiver for the Acme Packet 6100 features a blue clasp latch.
Acme Packet 6100 Hardware Installation and Maintenance Guide 95Caution To prevent damage to the optical lens, Acme Packet recommends that the protect
96 Acme Packet 6100 Hardware Installation and Maintenance Guide3. Holding the extended bale clasp latch with one hand, use your other hand to pull th
Acme Packet 6100 Hardware Installation and Maintenance Guide 973. Flip the bale clasp latch back into the rest position. Figure 6 - 132. Closing the
98 Acme Packet 6100 Hardware Installation and Maintenance GuideFan and Filter MaintenanceThis section explains how to remove a fan and replace the fi
Acme Packet 6100 Hardware Installation and Maintenance Guide 992. Using a small bladed screwdriver, unscrew the two captive screws at each corner of
100 Acme Packet 6100 Hardware Installation and Maintenance GuideFigure 6 - 138. Inserting the Fan into the Chassis Slot 2. Using a small bladed screw
Acme Packet 6100 Hardware Installation and Maintenance Guide 101requires that you remove the module itself. If you are not shutting down the Acme Pac
Acme Packet 6100 Hardware Installation and Maintenance Guide 3ESD Safety To protect the Acme Packet 6100 delicate electronic components from damage f
102 Acme Packet 6100 Hardware Installation and Maintenance GuideFigure 6 - 143. Removing the Air Filter from Behind the Front Bezel 5. Replace the ai
Acme Packet 6100 Hardware Installation and Maintenance Guide 1038. Place the air filter bracket behind the air filter, ensuring that the bracket lock
104 Acme Packet 6100 Hardware Installation and Maintenance Guide• Fan speed• Environmental sensor• Power supply• Voltage• Physical interface cardsEac
Acme Packet 6100 Hardware Installation and Maintenance Guide 105Fan Speed Alarms The following table lists the fan speed alarm. Table 6 - 10. Fan Spe
106 Acme Packet 6100 Hardware Installation and Maintenance GuideVoltage Alarms The following table lists the voltage alarms.Table 6 - 13. Voltage Ala
Table 6 - 15. Media Ethernet Link Alarm Information Alarm NameAlarm IDAlarm Severity Cause(s)Example Log MessageGraphic Display MessageLINK UP ALARM 1
108 Acme Packet 6100 Hardware Installation and Maintenance GuideWhen an SFP module is inserted or removed from an NIU, there is no impact on system h
Acme Packet 6100 Hardware Installation and Maintenance Guide 1097 SpecificationsIntroductionThis chapter provides information regarding the physical
110 Acme Packet 6100 Hardware Installation and Maintenance GuideDC Power Supply Physical DimensionsThis table lists the physical dimensions and weigh
Acme Packet 6100 Hardware Installation and Maintenance Guide 111Device Ratings This table lists the alarm device ratings of the Acme Packet 6100.Tab
4 Acme Packet 6100 Hardware Installation and Maintenance Guide
112 Acme Packet 6100 Hardware Installation and Maintenance GuideOptical Transceiver Interface Module SpecificationRefer to the following table for in
Acme Packet 6100 Hardware Installation and Maintenance Guide 1138 GlossaryAcronyms, Definitions, and TermsACLI — Acme Command Line Interface is the
114 Acme Packet 6100 Hardware Installation and Maintenance GuideIEC — International Electrotechnical CommissionIETF — Internet Engineering Task Force
Acme Packet 6100 Hardware Installation and Maintenance Guide 115SDRAM — Synchronous Dynamic Random Access Memory is a type of DRAM that can run at mu
116 Acme Packet 6100 Hardware Installation and Maintenance Guide
Acme Packet 6100 Hardware Installation and Maintenance Guide 117Index AAC power supply, physical dimensions of 109ACLI authentication 58acronyms 113A
118 Acme Packet 6100 Hardware Installation and Maintenance Guideconsole session 57control panelfront 9rear 9cooling components 20air inlets 20mainten
Acme Packet 6100 Hardware Installation and Maintenance Guide 119link up/link down alarm information 106log in, initial 58logging in 58Mmanagement int
120 Acme Packet 6100 Hardware Installation and Maintenance Guidepower supply removal and replacement 68powering on the chassis 58pre-installation 32R
Acme Packet 6100 Hardware Installation and Maintenance Guide 52 Component OverviewChassisThe Acme Packet 6100 is contained in a 1U rack-mounted chas
6 Acme Packet 6100 Hardware Installation and Maintenance Guideprevent the chassis from being overextended and requiring the user to unlock the clip t
Acme Packet 6100 Hardware Installation and Maintenance Guide 7Figure 2 - 9. Locking Clip Fastens the Chassis and Rack Slide Rails Once the chassis h
8 Acme Packet 6100 Hardware Installation and Maintenance Guidereset button, alarm LED, alarm silence button, console port, and USB port. The followin
Acme Packet 6100 Hardware Installation and Maintenance Guide 9Alarm LED The alarm LED on the front control panel indicates if any alarms are active o
10 Acme Packet 6100 Hardware Installation and Maintenance GuideNetwork Interface UnitThe single, hot-pluggable network interface unit (NIU) contains
Acme Packet 6100 Hardware Installation and Maintenance Guide 11other power switches. The System Power switch, located on the front panel of the NIU,
Copyright © 2014, 2015 Oracle and/or its affiliates. All rights reserved.This software and related documentation are provided under a license agreemen
12 Acme Packet 6100 Hardware Installation and Maintenance GuideConsole Port The console port, located on the Acme Packet 6100 front panel, provides
Acme Packet 6100 Hardware Installation and Maintenance Guide 13Figure 2 - 21. Console Adapter Alarm Port The alarm port on the NIU is a flexible inte
14 Acme Packet 6100 Hardware Installation and Maintenance GuideNetwork Management PortsThe Acme Packet 6100 has three network management ports locate
Acme Packet 6100 Hardware Installation and Maintenance Guide 15Ethernet ports for use. Set up the management interfaces using the physical and networ
16 Acme Packet 6100 Hardware Installation and Maintenance GuidePWR LED The green PWR LED indicates the operational state of the NIU. Mgmt 2Mgmt 1Mgm
Mgmt 2Mgmt 1Mgmt 0USBAlarmConsoleSystemPower OnStbyStbyDisLINK ACT LINK ACTPWR H/SPower Supply BPower Supply AGrounding TerminalsAcme Packet 6100 H
18 Acme Packet 6100 Hardware Installation and Maintenance Guidegrey locking handle, when moved from right to left, unlocks the power supply from the
Handle to Remove/Insert Power SupplyLocking Tab to Lock/Unlock Power Supply to Acme Packet 6100Acme Packet 6100 Hardware Installation and Maintenance
20 Acme Packet 6100 Hardware Installation and Maintenance GuideCooling ComponentsThe Acme Packet 6100 must remain well ventilated for reliable and co
Acme Packet 6100 Hardware Installation and Maintenance Guide 21Acme Packet 6100 Series Hardware ArchitectureThe Acme Packet 6100 series hardware is p
Acme Packet 6100 Hardware Installation Guide iiiContentsAbout This Guide. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
22 Acme Packet 6100 Hardware Installation and Maintenance Guide
Acme Packet 6100 Hardware Installation and Maintenance Guide 233 Graphic DisplayGraphic DisplayThe four-line graphic display located on the Acme Pac
24 Acme Packet 6100 Hardware Installation and Maintenance GuideDisplay ModesThe Acme Packet 6100 graphic display defaults to one of two display modes
Acme Packet 6100 Hardware Installation and Maintenance Guide 25The top menu displays only one category at a time. Press the Enter button to select a
26 Acme Packet 6100 Hardware Installation and Maintenance GuideINTERFACE Menu The INTERFACE menu allows you to scroll through a list of all configure
Acme Packet 6100 Hardware Installation and Maintenance Guide 27SYSTEM Menu The SYSTEM menu allows you to view system software, current time, and sysl
28 Acme Packet 6100 Hardware Installation and Maintenance Guide• Screen 4 — SNMP information: number of SNMP packets received, number of SNMP traps s
Acme Packet 6100 Hardware Installation and Maintenance Guide 29Graphic Display Output for HA NodesThe information included in this section only appli
30 Acme Packet 6100 Hardware Installation and Maintenance Guide
Acme Packet 6100 Hardware Installation and Maintenance Guide 314 System InstallationIntroductionThis chapter provides information about how to insta
iv Acme Packet 6100 Hardware Installation Guide 4 System Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
32 Acme Packet 6100 Hardware Installation and Maintenance GuideRecommended Tools and PartsAcme Packet recommends that you have the following parts on
Acme Packet 6100 Hardware Installation and Maintenance Guide 33console connector, reset button, graphic display buttons, and physical interface card
34 Acme Packet 6100 Hardware Installation and Maintenance GuideUnpacking the Acme Packet 6100To unpack the Acme Packet 6100:1. Inspect the external p
Acme Packet 6100 Hardware Installation and Maintenance Guide 35• Equipment rack slide rail (part of the slide rail assembly) Figure 4 - 39. Equipmen
36 Acme Packet 6100 Hardware Installation and Maintenance Guide• Mounting Spacer (2) Figure 4 - 42. Mounting Spacer • Phillips screws and flat head s
Acme Packet 6100 Hardware Installation and Maintenance Guide 37Mounting System Acme Packet provides flexible mounting options for your Acme Packet 61
38 Acme Packet 6100 Hardware Installation and Maintenance Guide3. For both holes in the flange, place one #10-32 x 5/8” screw through the mounting sp
Acme Packet 6100 Hardware Installation and Maintenance Guide 396. For both holes in the slide rail flange, place one #10-32 x 5/8” screw through the
40 Acme Packet 6100 Hardware Installation and Maintenance Guide2. Line up the painted side of the stationary rail with an appropriate mount point on
Acme Packet 6100 Hardware Installation and Maintenance Guide 416. Expand and line up the unpainted side of the stationary rail flange on the outside
Acme Packet 6100 Hardware Installation Guide v7 Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
42 Acme Packet 6100 Hardware Installation and Maintenance Guide2. Line up one chassis flange with the tapped holes. Position the chassis flange’s spr
Acme Packet 6100 Hardware Installation and Maintenance Guide 43Installing the Chassis in the RackThe Acme Packet 6100 is now ready to be installed in
44 Acme Packet 6100 Hardware Installation and Maintenance Guide4. Line up the chassis-mounted thumbscrews with the threads on the Acme Packet 6100 mo
Acme Packet 6100 Hardware Installation and Maintenance Guide 45To install your Acme Packet 6100 in a center-mount configuration: 1. Locate the follow
46 Acme Packet 6100 Hardware Installation and Maintenance Guideshould hold the Acme Packet 6100 in the correct position while the other person screws
Acme Packet 6100 Hardware Installation and Maintenance Guide 47Caution The Acme Packet 6100 does not support mixing AC and DC power supplies in the s
48 Acme Packet 6100 Hardware Installation and Maintenance Guide2. Place the lug on the end of the grounding cable onto the grounding posts. Figure 4
Acme Packet 6100 Hardware Installation and Maintenance Guide 491. Set the System Power switch to the Stby position to cut off power to the Acme Packe
50 Acme Packet 6100 Hardware Installation and Maintenance GuideDC Power Cord InstallationThis section shows you how to install a DC power cord.Cautio
Acme Packet 6100 Hardware Installation and Maintenance Guide 514. Connect the plug from another 3-conductor power cord to the power connector located
vi Acme Packet 6100 Hardware Installation Guide
52 Acme Packet 6100 Hardware Installation and Maintenance GuideNote: Intra-building ports include Media and Signaling Network Interfaces, Network Ma
Acme Packet 6100 Hardware Installation and Maintenance Guide 532. Insert the RJ45 connector on the end of the alarm port cable into the alarm port la
54 Acme Packet 6100 Hardware Installation and Maintenance Guide10GbE SFP Optical Cabling ProcedureThis section explains how to cable a Acme Packet 61
Acme Packet 6100 Hardware Installation and Maintenance Guide 554. Repeat Steps 1 through 2 for each additional fiber optic cable you connect to your
56 Acme Packet 6100 Hardware Installation and Maintenance Guide3. Refer to the configuration procedures located in the HA Nodes chapter of the Acme P
Acme Packet 6100 Hardware Installation and Maintenance Guide 575 StartupIntroductionThis chapter describes Acme Packet 6100 startup which involves t
58 Acme Packet 6100 Hardware Installation and Maintenance Guide4. If you have created the console connection before powering up the Acme Packet 6100,
Acme Packet 6100 Hardware Installation and Maintenance Guide 59System access in the following procedure uses the default User and Superuser passwords
60 Acme Packet 6100 Hardware Installation and Maintenance Guide
Acme Packet 6100 Hardware Installation and Maintenance Guide 616 Maintenance IntroductionIntroductionThis chapter explains Acme Packet 6100 hardware
Acme Packet 6100 Hardware Installation and Maintenance Guide vii About This GuideOverviewThe Acme Packet 6100 is a session border controller (SBC)
62 Acme Packet 6100 Hardware Installation and Maintenance GuideRebooting, Resetting, and Power CyclingReboot Rebooting the Acme Packet 6100 shuts dow
Acme Packet 6100 Hardware Installation and Maintenance Guide 63During a system reset, certain files are not closed properly, and they may become corr
64 Acme Packet 6100 Hardware Installation and Maintenance GuideOnce you have determined that the Acme Packet 6100 due for maintenance is in standby m
NETNETSBC1# show health Media Synchronized true SIP Synchronized true MGCP Synchronized true
66 Acme Packet 6100 Hardware Installation and Maintenance Guide2. Confirm that current configurations of both the active and standby Acme Packet 6100
Acme Packet 6100 Hardware Installation and Maintenance Guide 67When this Acme Packet 6100 returns online, it will synchronize its HA state with the a
68 Acme Packet 6100 Hardware Installation and Maintenance Guide6. When mounted in slide rails, the chassis will stop when the locking clip pin on the
Acme Packet 6100 Hardware Installation and Maintenance Guide 69power supply, remember to first ground yourself using appropriate ESD grounding equipm
70 Acme Packet 6100 Hardware Installation and Maintenance Guide4. Continue pulling the power supply towards you until it is completely out of the cha
Acme Packet 6100 Hardware Installation and Maintenance Guide 71NIU Removal and ReplacementPrior to removing an NIU, the platform in which it is insta
viii Acme Packet 6100 Hardware Installation and Maintenance GuideRevision HistoryThis section contains a revision history for this document.Date Desc
72 Acme Packet 6100 Hardware Installation and Maintenance Guide6. Pull the loosened NIU out of the Acme Packet 6100 by holding each side of the NIU’s
Acme Packet 6100 Hardware Installation and Maintenance Guide 735. Slide the card into the Acme Packet 6100. The physical interface card circuit board
74 Acme Packet 6100 Hardware Installation and Maintenance Guide8. Screw the NIU into the chassis with a #2 Phillips screwdriver. This creates the fin
Acme Packet 6100 Hardware Installation and Maintenance Guide 75connector supports one side of the module while the other side of the SSM3 module rest
76 Acme Packet 6100 Hardware Installation and Maintenance GuideRequired Parts The following parts are required to replace the SSM3 module:• ESD wris
Acme Packet 6100 Hardware Installation and Maintenance Guide 77• Standoff screws (stored after removing the SSM3 module or available with the new SSM
StandoffsSSM3 Module78 Acme Packet 6100 Hardware Installation and Maintenance GuideFigure 6 - 109. Location of the SSM3 Module Standoff Posts Instal
Acme Packet 6100 Hardware Installation and Maintenance Guide 79Figure 6 - 111. Process for Installing the SODIMM (l-r) Pre-Installation Guidelines P
80 Acme Packet 6100 Hardware Installation and Maintenance Guide• ESD wrist strap• ESD safe location• SODIMM(s) • NIU Card Removing the SODIMM(s)The f
Acme Packet 6100 Hardware Installation and Maintenance Guide 815. Grasping the SODIMM between your thumb and index finger, pull the component out of
Acme Packet 6100 Hardware Installation and Maintenance Guide 11 Safety IntroductionThis chapter provides an overview of the recommended safety preca
82 Acme Packet 6100 Hardware Installation and Maintenance GuideFigure 6 - 116. Installing the SODIMM (l-r) 5. Using the index finger and thumb of yo
Acme Packet 6100 Hardware Installation and Maintenance Guide 83Upgrading or Replacing a Solid State Drive This section explains how to upgrade or rep
84 Acme Packet 6100 Hardware Installation and Maintenance GuideThe following is an overview of the power and ground cabling removal process:1. Shut o
Acme Packet 6100 Hardware Installation and Maintenance Guide 85Removing Hardware in Center-Mount ConfigurationsThe rack ears must be removed before y
86 Acme Packet 6100 Hardware Installation and Maintenance GuideFigure 6 - 118: Figure 2 - 35: Left chassis slide.3. Remove the the two countersunk sc
Acme Packet 6100 Hardware Installation and Maintenance Guide 872. Set these screws aside.REARFRONT3. Unscrew the seven countersunk screws on the top
88 Acme Packet 6100 Hardware Installation and Maintenance Guide1. The SSD is located at the front of the motherboard, on the left side as you view it
Acme Packet 6100 Hardware Installation and Maintenance Guide 893. Identify the SATA connector attached to the SSD.REARFRONT Screws SATAConnection to
90 Acme Packet 6100 Hardware Installation and Maintenance Guide5. Hold the SSD in one hand, and the SATA connector in the other, and gently disconnec
Acme Packet 6100 Hardware Installation and Maintenance Guide 91Postinstallation After the Solid State Drive has been installed in the Acme Packet 610
Komentarze do niniejszej Instrukcji